自由口通讯设定:    

LD     SMO.1
MOVB   16#09, SMB30
MOVB   16#BC, SMB87
MOVB   16#OD.SMB89
MOVB    5, SMB92
MOVB    59, SMB94
LD         SMO.1
ATCH    INT_O, 9
ATCH    INT_1, 23
ENI
LD          SMO.1
MOVB    6, VB200
MOVB   16#7E, VB201
MOVB   16#03, VB202
MOVB   16#FD, VB203
MOVB   16#50, VB204
MOVB   16#BO, VB205
MOVB   16#OD, VB206
LD          bSMO.1
MOVB    6, VB210
MOVB   16#7E, VB211
MOVB   16#04, VB212
MOVB   16#FC, VB213
MOVB   16#50, VB214
MOVB   16#BO, VB215
MOVB   16#OD, VB216
LD         SMO.1
MOVW   +O,VW220
LD         SMO.1
O           Q10.3
O           T41
LPS
AN         T39
=            Q10.3
LPP
TON       T39, +5
 
LD          T39
O            Q10.4
LPS
AN          T40
=             Q10.4
LPP
TON       T40, +5
LD          T40
O            Q10.5
LPS
AN          T41
=             Q10.5
LPP
TON       T41, +5
LD          Q10.4
EU
AB<>      SMB86, 0
+1          +1, VW220
LD          Q10.4
AW=       VW220, +1
EU
AB<>      SMB86, 0
XMT        VB200, 0
LD          Q10.4
AW=       VW220, +2
EU
AB<>     SMB86, 0
XMT       VB210, 0
MOVW  +O.VW220
数据处理:
INTO:
LD        SMO.O
RCV     VB100, 0
INTl:
LD        SMO.O
MOVD  &VB101, AC1
MOVD  &VB601, AC2
R           M0.2, 1
R           M0.3, 1
LD        SMO.O
MOVW +O,VW898
LD        SMO.O
FOR     VW898, +1, +58
LD        M0.2
LPS
AB=      *ACl, 16#00
MOVB  16#05,'AC2
AENO
+1          +1, AC2
LPP
AB=        * ACl, 16#08
MOVB    16#OD,'AC2
AENO
+1           +1, AC2
LD          M0.2
-              M0.3
LD          M0.2
R            M0.2, 1
LDN       M0.3
AB=        *ACl, 16#05
-              M0.2
LDN       M0.3
AN          M0.2
AB<>    *ACl, 16#05
MOVB   *ACl,'AC2
AENO
+I           +1, AC2
 LD        SMO.O
+l           +1, AC1
 RM0.3,1
 NEXT
 LD        SMO.O
SWAP   VW611
SWAP   VW613
SWAP   VW615
SWAP   VW617
SWAP   VW619
SWAP   VW621
 SWAP  VW623
 SWAP  VW625
 SWAP  VW627
 SWAP  VW629
LDB=    VB601,  16#7E
AB=      VB602,  16#03
AB=      VB603, 16#FD
AB=      VB604,  16#50
BMB     VB605, VB301, 26
LDB=    VB601,  16#7E
AB=      VB602,  16#04
AB=      VB603, 16#FC
AB=      VB604,  16#50
BMB     VB605, VB331, 26

具体通讯协议请参照西南自动化研究所的WTC-B-02通讯协议。

2) EM231负责部分模拟量采集,A/D变化,DC0~5V信号,处理好数字滤波和模拟地共地问题。

3)触摸屏负责定值设定、控制和数据显示。

4)西南自动化研究所1891A等智能变量变送器负责两段母线电量参数的采集和处理。